MIURA SI-Series
Industrial steam system
Brand: MIURA
MIURA SI slim and compact single-pass steam boilers have an output of 2000-2500 kg/h. The manufacturer states efficiency of 98% on gas and 95% on diesel; the continuous pilot flame responds quickly to load changes.




Features
- Output: 2,000–2,500 kg/h
- Efficiency on gas fuel: 98%
- Efficiency on diesel fuel: 95%
- Safety alarm system
- The panel shows operating status with color indicators and text; water and steam supply are controlled automatically at the press of a button.
- The alarm function helps with preventive maintenance and avoiding unexpected shutdowns.
- Panel languages: English, Simplified Chinese, Traditional Chinese, Korean and Japanese.
- The panel displays operating data including steam output and boiler blowdown.
- The flame sensor detects its own malfunctions; the protective steam pressure switch works on the principle of the heated magnet losing its magnetic force.
- MOM communication automatically notifies the service center when a fault is detected.
- Placing boilers close together saves space and enables multi-boiler operation.
- On SI gas models, continuous pilot control helps combustion start quickly on sudden load changes, keeps steam pressure stable, and reduces purge losses during startup/shutdown.
- On SI gas models, an inverter is standard: fan speed is regulated according to the air required for combustion.
Specifications
| Boiler type | Single-pass steam boiler |
|---|
| Steam output | 2000–2500 kg/hour |
|---|
| Max. working pressure | 0.98 MPa |
|---|
| Efficiency | Gas: 98%, diesel: 95% |
|---|
| Power supply | AC 380 V, 50 Hz, 3 phase |
|---|
| Fuel | Natural gas / LPG, diesel |
|---|